55 Lift Down Coil Fault

Kone · Elevator Control

Was bedeutet 55 ?

A fault has been detected in the lift down coil, indicating an electrical issue with the solenoid responsible for lowering the platform. This disables both lifting and driving functions.

Häufige Ursachen

  • Lift down coil open circuit, short circuit, or high resistance.
  • Damaged wiring or loose connections to the lift down coil.
  • Control circuit failure attempting to activate the coil.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the nominal supply voltage at the terminals connected to the lift down solenoid coil.

  2. 2

    Inspect the wiring harness and connectors leading to the lift down solenoid coil for any visible damage, chafing, or loose connections.

  3. 3

    Measure the resistance of the lift down solenoid coil (with power disconnected) and compare it against the specified value in the Kone Kone service manual.

  4. 4

    Check the output status and voltage from the Kone Kone Elevator Control unit's relevant output terminal to ensure it is commanding the lift down solenoid correctly.

  5. 5

    Inspect the mechanical plunger and linkage of the lift down solenoid for free movement and any obstructions that could prevent its proper operation.