Übersetzen...
26033
Ground fault, KPP/KSP (axis)
Kuka · KR C4 Controller
Was bedeutet 26033 ?
This fault indicates a power unit overcurrent due to a ground fault in the motor or motor cable connected to a KPP/KSP drive. A ground fault poses a significant safety risk and can cause severe damage to electrical components.
Häufige Ursachen
- Ground fault in the motor cable
- Internal ground fault within the motor
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Inspect the motor cable for insulation breakdown or damage that could cause a ground fault.
- 2
Check the motor for internal ground faults by measuring insulation resistance.
- 3
Reinitialize the drive bus by cycling Power Off / Power On.
- 4
Check the KSP module for any status indicators.
- 5
Check the KPP module for any status indicators.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Kuka KR C4 Controller