26032

IxT overload error, KPP/KSP (axis)

Kuka · KR C4 extended

Was bedeutet 26032 ?

The axis is overloaded, indicated by the IxT (Current x Time) monitoring function. This fault suggests that the mean continuous current is too high, potentially leading to overheating and damage to the motor or drive.

Häufige Ursachen

  • Excessive load in the program during start-up or operation.
  • Modifications made to the system (e.g., increased payload, changed mechanics).
  • Temperature influences (e.g., high ambient temperature).
  • CBS pressure issue.
  • Gear unit fault.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Review robot program to identify and reduce excessive load.

  2. 2

    Reinitialize the drive bus: Power Off / Power On.

  3. 3

    Check machine for mechanical issues or resistance.

  4. 4

    Check trace recording of axis current.

  5. 5

    Adapt program velocity to reduce continuous load.

  6. 6

    Check CBS pressure.