26045
Hardware fault, KPP/KSP (axis)
Kuka · KR C4 Operating Instructions
Was bedeutet 26045 ?
The KPP or KSP device has detected an internal hardware fault. This indicates a critical issue within the device's internal electronics that requires direct attention to the component itself.
Häufige Ursachen
- Hardware malfunction detected in the KPP/KSP drive or associated control module.
- Encoder failure or signal loss for the axis.
- Motor driver fault within the KPP/KSP unit.
- Over-temperature condition within the KPP/KSP hardware.
- Internal communication error on the KPP/KSP bus.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Reinitialize the drive bus by performing a Power Off / Power On cycle of the entire system.
- 2
Check the specific KPP/KSP device's LEDs for further diagnostic information or specific fault indicators.
- 3
Exchange the defective KPP/KSP device, as the fault is internal hardware-related.