10039
PROFIBUS Master Error in Module
Kuka · KR C4 PROFIBUS
Was bedeutet 10039 ?
The PROFIBUS master encountered an error within a specific module, identified by its name and further detailed by an internal error code. This suggests a component-specific issue on the PROFIBUS master. Refer to the PROFIBUS master's manufacturer documentation for details on the specific error code.
Häufige Ursachen
- The PROFIBUS master detected an internal error within a specific slave module.
- A slave module on the PROFIBUS network returned an invalid response to the master.
- Corrupted data packets originating from or intended for the module.
- The module's firmware is incompatible with the master's protocol version.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Identify the faulty module by its PROFIBUS address from the error message.
- 2
Check the status indicator on the identified PROFIBUS module.
- 3
Disconnect the problematic module from the PROFIBUS network and observe if the error clears.
- 4
Review the PROFIBUS diagnostic logs for detailed information on the module's communication.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026