1605
Error reading TRACE.DEF
Kuka · KRC2 KSS System Message
Was bedeutet 1605 ?
The 'TRACE.DEF' file could not be read at the start of trace recording, preventing the recording from being carried out.
Häufige Ursachen
- Unable to access or read the TRACE.DEF file from storage media.
- Corrupted TRACE.DEF file.
- Incorrect file path or filename specified for TRACE.DEF.
- Permission issues preventing the system from reading TRACE.DEF.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Ensure the 'TRACE.DEF' file is available in the correct location.
- 2
Start or check the FTP server responsible for providing the file.