344
No multiplex feature for DSE-channel
Kuka · KRC2 KSS System Message
Was bedeutet 344 ?
Force mode is activated, but the RDC (Robot Drive Controller) does not have the required plug-on card for multiplex operation. Consequently, force mode will not be activated.
Häufige Ursachen
- Attempted to use a multiplex feature on a DSE-channel which does not support it.
- The specific DSE-channel hardware or software configuration does not allow for multiplexing.
- Feature not enabled or available for the current channel setup.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Connect the appropriate RDC plug-on card for multiplex operation.
- 2
Explicitly deactivate force mode if multiplex operation is not required.