Übersetzen...
0220

noT-Fkt Credit

Lenze · 9300 Series

Was bedeutet 0220 ?

The controller lacks the necessary technology units to execute a loaded program containing technology functions. This indicates a mismatch between the program's requirements and the controller's hardware capabilities.

Häufige Ursachen

  • PLC program was developed for a controller with higher technology unit capacity (e.g., more integrated motion axes, advanced PID functions) than the current hardware model.
  • Licensing error or missing license key for specific technology functions (e.g., `Camming`, `Flying_Shear`) required by the loaded program.
  • Downgraded controller firmware that no longer supports certain technology functions, or older firmware lacking capabilities used in the current program.
  • Attempting to use a technology function beyond the hardware's physical limits (e.g., trying to control 4 axes on a 2-axis licensed controller).
  • Corrupted license data or incorrect controller configuration (e.g., parameter `P2-01` set incorrectly for enabled features) preventing technology unit detection.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    1. Compare the controller's part number and specified technology unit capabilities with the requirements of the loaded PLC program (e.g., number of axes, available function blocks).

  2. 2

    2. Verify that all necessary software licenses for technology functions are correctly installed and activated on the controller, checking license status via the engineering tool.

  3. 3

    3. Update the controller firmware to the latest version compatible with the installed PLC program and required technology functions.

  4. 4

    4. Modify the PLC program to remove unsupported technology functions or re-implement them using basic functions that are available on the current controller hardware.

  5. 5

    5. Check controller configuration parameters (e.g., `P2-01` for enabled features, `P2-02` for axis count) to ensure they match the physical hardware and intended use.

Alle Codes in diesem Handbuch durchsuchen (145)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes