Error in parameter set
Lenze · 9300 Series
Was bedeutet PR0 ?
This error occurs when the operating system software has been updated and requires the storage of the Lenze setting to ensure compatibility. This typically happens after a firmware upgrade.
Häufige Ursachen
- Firmware update changed the internal parameter mapping or data structure, making the old parameter set incompatible.
- Failure to save the updated default parameters after a firmware upgrade, causing a mismatch with the new operating system.
- Incomplete firmware update process, resulting in a partially updated operating system that cannot correctly interpret parameters.
- Discrepancy between the loaded application software and the underlying firmware, requiring a parameter re-initialization.
- Corrupted system parameter block during the update, preventing the device from loading any valid configuration.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Immediately save the current parameter set after a firmware update (e.g., using P0-01 = 1) to align with the new OS.
- 2
Re-load the latest compatible firmware version, ensuring the entire update process completes without interruption.
- 3
Perform a factory reset (e.g., using parameter P0-01 = 0) to re-initialize all parameters to their default values compatible with the new firmware.
- 4
Manually re-enter critical application parameters or load a known compatible backup parameter file after the factory reset.
- 5
Verify the firmware version displayed on the device (e.g., parameter C0000) matches the expected version for the parameter set.
- 6
Cycle power to the device after saving or loading parameters to ensure the changes are fully applied and validated.