Übersetzen...
x086

Sd6 Thermal sensor error at motor (X7 or X8)

Lenze · 9300 Series

Was bedeutet x086 ?

An error has been detected with the thermal sensor connected to the motor inputs X7 or X8. This indicates a malfunction of the sensor itself or an issue with its wiring, preventing accurate motor temperature monitoring. This monitoring is controlled by parameter C0594.

Häufige Ursachen

  • Broken wiring, short circuit, or loose connection in the thermal sensor circuit connected to terminals X7 or X8.
  • Damaged or faulty thermal sensor (e.g., PTC thermistor, KTY sensor) installed in the motor windings.
  • Sensor out of its specified operating range (e.g., open circuit or resistance too low/high) detected by the drive.
  • Improper sensor type selected in the drive's parameters (e.g., P3-10 for KTY sensor type).
  • Electrical noise or interference on the sensor wiring causing erratic readings.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Disconnect the thermal sensor wires from X7 or X8 and measure the sensor's resistance directly at the motor leads with an ohmmeter (compare to sensor datasheet).

  2. 2

    Inspect the entire length of the thermal sensor cable from the motor to the drive's terminals X7/X8 for breaks, chafing, or corrosion.

  3. 3

    Verify the parameter setting for the motor thermal sensor type (e.g., P3-10 for PTC or KTY) matches the installed sensor.

  4. 4

    Check for proper grounding and shielding of the thermal sensor cable to minimize electrical noise pick-up.

  5. 5

    If the sensor resistance is outside normal limits or wiring is confirmed good, consider replacing the motor's integrated thermal sensor.

Alle Codes in diesem Handbuch durchsuchen (145)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes