E51
Power Transistor Overheat
Mitsubishi Electric · FR-D700 Inverter
Was bedeutet E51 ?
The power transistor has overheated, indicating excessive heat generation, potentially due to a fault or overload condition. This protects the inverter from damage.
Häufige Ursachen
- Overheating of the inverter's power transistors due to insufficient cooling.
- Excessive current draw through the power transistors.
- Faulty heatsink thermal paste or inadequate fan operation for the inverter.
- Short-term overload condition during motor startup.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Inspect the inverter unit's heatsink for dust accumulation and ensure proper ventilation clearances.
- 2
Verify the outdoor fan operation is providing adequate cooling to the inverter components, checking fan speed and direction.
- 3
Measure the current draw of the compressor and compare to specification, checking for overload conditions.
- 4
Check for loose electrical connections within the inverter module's power circuit.