37810000 hex

Process Data Object Setting Missing

Omron · NJ/NY-series NC Integrated Controller

Was bedeutet 37810000 hex ?

A minor fault indicating incorrect Process Data Object (PDO) mapping within the CNC Function Module for a CNC coordinate system. This fault is detected at instruction execution. While the user program continues, operations for the relevant CNC coordinate systems are not possible.

Häufige Ursachen

  • Required Process Data Objects (PDOs) for the CNC instruction are not correctly mapped.
  • A CNC instruction was executed for a device that lacks the necessary object support for that instruction.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify and correct the PDO mapping for the specific CNC instruction in use, ensuring all required PDOs are configured and mapped.

  2. 2

    Consult the device manual to confirm whether the device supports the specific CNC instruction being executed.

  3. 3

    Modify the CNC program to ensure that only supported instructions are executed on the target device.