Inlet Blocked

Coin Inlet Blocked

Otis · 400 Elevator

Was bedeutet Inlet Blocked ?

Indicates two coins were sensed at the inlet sensor but failed to make it to the changer within 10 seconds. This suggests a blockage or malfunction in the coin path between the inlet and the changer.

Häufige Ursachen

  • Obstruction in the coin path after the inlet sensor, preventing coins from reaching the changer.
  • Malfunction of the coin routing mechanism.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the coin inlet and the coin path between the inlet and the changer for any foreign objects, debris, or mechanical obstructions.

  2. 2

    Verify the functionality of the inlet sensor and any subsequent coin path sensors by testing with known coins or observing diagnostic feedback.

  3. 3

    Inspect the coin path for signs of wear, misalignment, or damage to guides, gates, or other moving parts that could impede coin travel.

  4. 4

    Check all electrical connections and wiring between the coin inlet system and the coin changer unit for looseness, corrosion, or damage.

  5. 5

    Clean the coin path thoroughly to ensure smooth coin travel and remove any build-up that could increase friction or cause intermittent blockages.