411

MAX AUTO-RESETS ATTEMPTED

Otis · DSD 412 DC Elevator Drive

Was bedeutet 411 ?

More than 5 automatic resets were necessary in less than 20 minutes of accumulated time. An accumulation of 5 counted faults will cause this fault and require a manual reset for continued operation.

Häufige Ursachen

  • Frequent underlying fault conditions causing repeated auto-resets.
  • Five fault counts accumulated within a 20-minute period.
  • Parameter #101 (Auto Fault Reset) is enabled.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Identify and resolve the primary fault condition causing multiple resets.

  2. 2

    Manually reset the drive to clear the fault.

  3. 3

    Consider setting Function #101 (Auto Fault Reset) to 0 (Off) if automatic resets are not desired.