RIPPLE FAULT
Otis · DSD 412 DC Elevator Drive
Was bedeutet 909 ?
Repeated instances of high peak-to-average motor armature current are detected. This condition can be caused by defective hardware, inadequate regulator tuning, or other oscillatory operating conditions.
Häufige Ursachen
- Defective hardware components, which can be diagnosed using the PCU Diagnostics CDU function #998.
- Poor tuning or configuration of the drive's current regulator.
- Other conditions leading to oscillatory operation within the motor or drive system.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Execute the PCU Diagnostics CDU function #998 to identify any defective hardware.
- 2
Review and adjust the drive's regulator tuning parameters to stabilize current ripple.