401
EXCESSIVE FIELD CURRENT
Otis · DSD 412 Elevator System
Was bedeutet 401 ?
This fault signifies that the measured motor field current has exceeded 125% of the rated current, as defined by parameter #50. This condition can lead to motor field damage.
Häufige Ursachen
- Partially shorted motor field coil, drawing excessive current.
- Incorrect data entry in parameters #49, #50, #51, #52, #54, & #55, leading to an unstable motor field current regulator.
- Mis-wiring of module A3, resulting in incorrect phasing.
- Incorrect current tap selected at A3, TB4, or an improper A3 SW1 setting.
- Malfunction within the motor field power circuit, possibly in module A3.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the motor field winding for any signs of a partially shorted coil.
- 2
Review and verify the settings for parameters #49, #50, #51, #52, #54, and #55.
- 3
Verify that the wiring phasing for module A3 is correct.
- 4
Check and verify the current tap setting at A3, TB4, and the calibration switch A3 SW1 setting.
- 5
Inspect module A3 for any malfunction in the motor field power circuit.