Übersetzen...
Ot
Overtorque
Schindler · Altivar 212 Variable Frequency Drive
Was bedeutet Ot ?
This fault occurs when the calculated motor torque reaches or exceeds the level set by parameter F616 ([Overtorque level]), indicating that the motor is operating under excessive load and could be damaged.
Häufige Ursachen
- Calculated motor torque has reached the level set by parameter F616.
- Excessive mechanical load on the motor.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Adjust the settings of parameters F615 ([Overtorque det.]) and F616 ([Overtorque level]) as needed.
- 2
Verify the machine operation to identify any mechanical binding or obstructions causing high torque.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Schindler Altivar 212 Variable Frequency Drive