Übersetzen...
CFF

INCORRECT CONFIG.

Schindler · Altivar 312 Drive

Was bedeutet CFF ?

This fault indicates that the current drive configuration is inconsistent, possibly due to the addition or removal of an option card. An inconsistent configuration can prevent proper drive operation.

Häufige Ursachen

  • The drive's internal configuration data is inconsistent.
  • An option card has been added to or removed from the drive without a configuration update.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Return the drive to its factory settings.

  2. 2

    Retrieve and load a previously backed-up configuration, if it is valid. Refer to the [Restore config.] (FCS) parameter (page 46).

Alle Codes in diesem Handbuch durchsuchen (32)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes