38

Internal error

SEW Eurodrive · Drives

Was bedeutet 38 ?

An unspecified internal error has occurred within the MOVIMOT® inverter. This type of error usually requires specialized diagnostic tools and expertise.

Häufige Ursachen

  • Unspecified internal system malfunction.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify input supply voltage (L1, L2, L3) at the MOVIMOT® inverter's main power terminals against the rated nominal voltage.

  2. 2

    Inspect the motor cable for any visible damage, chafing, or signs of stress, and check all motor connections (U, V, W, PE) for tightness and proper termination.

  3. 3

    Check all operational and motor-specific parameter settings within the MOVIMOT® inverter using SEW diagnostic software (e.g., MOVITOOLS® MotionStudio) for correctness and compare with the last known good configuration.

  4. 4

    Measure the insulation resistance of the motor windings to ground and phase-to-phase with the MOVIMOT® inverter disconnected, ensuring it meets manufacturer specifications.

  5. 5

    Perform a complete power cycle of the MOVIMOT® inverter by disconnecting and reconnecting the main power supply, then monitor for fault reoccurrence.