Copy error

SEW Eurodrive · Drives

Was bedeutet 97 ?

An error occurred during the transmission of a parameter set or during a copy process. This typically happens if the DBG keypad or PC is disconnected, or the 24 V supply voltage is interrupted while copying data.

Häufige Ursachen

  • DBG keypad or PC disconnected during the copy process
  • 24 V supply voltage switched off during the copying process
  • 24 V supply voltage switched on during the copying process

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Load the factory setting using the DBG keypad or MOVITOOLS® MotionStudio software

  2. 2

    Load the complete data record from the previous MOVIMOT inverter using the DBG keypad or MOVITOOLS® MotionStudio software

  3. 3

    Acknowledge and reset the error