FF0208h
Lag Error Exceeded
SEW Eurodrive · MOVI-PLC SyncCrane Application
Was bedeutet FF0208h ?
This fault occurs when the defined lag error window is exceeded in automatic mode. The lag error represents the distance from the external encoder position to the virtual master encoder position. Exceeding this set tolerance causes the axis system to stop to maintain synchronized operation.
Häufige Ursachen
- The actual position deviates from the commanded position beyond a defined tolerance.
- Motor encoder feedback is not keeping up with motion demands.
- Inadequate servo loop tuning leading to excessive tracking error.
- Mechanical load or inertia exceeding controller capabilities.
- High acceleration or velocity commands causing position lag.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review the configured 'Lag error window' startup parameter to ensure it is appropriate for the application's synchronization requirements.