0012
Read access only
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Was bedeutet 0012 ?
This PROFIBUS-DP additional code (Error Class 8, 'Other Error') occurs when an attempt was made to write to a parameter via PROFIBUS-DP that is designated as read-only. The inverter rejects the write request for parameters that cannot be modified.
Häufige Ursachen
- Attempting to write a value to a parameter that is configured for read-only access.
- Security setting prevents modification of this specific parameter.
- Parameter is dynamically set and cannot be manually overwritten.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.