Setpoint Source Not Defined

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

Was bedeutet 33 ?

Immediate switch-off because the setpoint source (e.g., analog input, fieldbus, internal parameter) is either not defined or incorrectly configured. The inverter cannot determine how to receive its target values for speed, position, or torque.

Häufige Ursachen

  • The source for setpoint commands (e.g., analog input, fieldbus) is not defined in the configuration.
  • No valid setpoint source selected in operating parameters.
  • Startup error where setpoint source is not configured before operation.
  • Invalid parameter setting for setpoint source selection.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Set the correct setpoint source using parameter P100.