Technology Function Mismatch
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Was bedeutet 87 ?
Immediate switch-off caused by an attempt to load a parameter set intended for an application version unit with an activated technology function into a standard version unit. This signifies an incompatibility between the loaded configuration and the inverter's hardware/firmware capabilities.
Häufige Ursachen
- The selected technology function (e.g., specific motion profile) does not match the drive's capabilities or configuration.
- Attempting to use a feature not supported by the current firmware or hardware.
- Mismatch between application requirements and configured technology function.
- Invalid parameter selection for technology function.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Activate the factory settings (P802 = YES) to clear the incorrect parameter set.
- 2
Reset the unit to initialize with standard settings.