Übersetzen...
11
Thermal overload of the output stage or internal unit error
SEW Eurodrive · MOVIFIT-FC Inverter
Was bedeutet 11 ?
The output stage of the unit has experienced thermal overload, or an internal error has occurred. This suggests that the operating temperature of the output stage is too high due to ambient conditions, inadequate heat dissipation, or excessive drive load, risking hardware damage.
Häufige Ursachen
- Output stage overheating due to sustained high load.
- Internal fault within the power module's heatsink monitoring.
- Fan failure or blockage affecting heatsink cooling.
- Parameter P0626 (output stage thermal model) inaccurate.
- Overcurrent condition leading to output stage stress.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Lower the ambient temperature surrounding the unit.
- 2
Ensure proper ventilation around the unit to prevent heat build-up.
- 3
Reduce the mechanical load on the drive.
- 4
Reset the fault by switching off the DC 24 V supply voltage.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: SEW Eurodrive MOVIFIT-FC Inverter