Übersetzen...
F00058

BOP contents incompatible

Siemens · SINAMICS G120

Was bedeutet F00058 ?

An attempt was made to clone parameters using a Basic Operator Panel (BOP) that contains parameters created on a different type of drive. This incompatibility prevents successful parameter transfer, as the configurations are not designed for the current drive, leading to configuration errors.

Häufige Ursachen

  • The BOP contains parameters from a different drive model or series (e.g., cloning parameters from a G120 to a G130 drive).
  • Firmware version mismatch between the drive and the BOP (e.g., older BOP firmware on a newer drive).
  • Parameter set created for a different power size or configuration of the same drive series.
  • Attempting to clone parameters with specific hardware features not present in the target drive (e.g., different I/O configuration).
  • Corruption of the parameter file on the BOP, leading to an incorrect drive type identification.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the BOP's part number and the drive's model number to ensure they are compatible for parameter transfer.

  2. 2

    Check the firmware versions of both the drive and the BOP; update firmware if a known compatibility issue exists.

  3. 3

    Perform a factory reset of the BOP to clear its incompatible contents, then attempt to clone from the drive (if the drive has a valid configuration).

  4. 4

    Instead of cloning, try to manually input essential parameters into the drive if the BOP can still function as an interface.

  5. 5

    If parameters are being loaded from an external source (e.g., SD card, PC), ensure the parameter file matches the target drive's exact model and configuration.

Alle Codes in diesem Handbuch durchsuchen (109)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes