Vac-Bfr/Vac-Srr
AC Grid Voltage Outside Allowable Range
SMA · SUNNY BOY 5000US-8000US Solar Inverter
Was bedeutet Vac-Bfr/Vac-Srr ?
The AC grid voltage has exceeded or fallen below the allowable operating range for the Sunny Boy SB50US-80US-IUS094030. This can also be caused by a disconnected grid or a disconnected AC cable. The inverter assumes a public grid outage and disconnects to prevent islanding. 'Bfr' and 'Srr' are internal processor messages.
Häufige Ursachen
- AC grid voltage exceeding the allowed upper limit (>Vac Max).
- AC grid voltage falling below the allowed lower limit (<Vac Min).
- Disconnected public grid.
- Disconnected AC cable to the grid.
- Rapid change in grid voltage.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the condition of the grid at the AC terminal blocks within the Sunny Boy SB50US-80US-IUS094030.
- 2
Inspect the AC disconnect between the Sunny Boy and the grid.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026