Übersetzen...
7015

Fault sensor interior temperature

SMA · SUNNY TRIPOWER X Solar Inverter

Was bedeutet 7015 ?

An internal temperature sensor within the inverter is defective. This fault causes the inverter to interrupt its feed-in operation to prevent potential overheating or damage due to inaccurate temperature monitoring.

Häufige Ursachen

  • Defective internal temperature sensor.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the inverter's ambient operating temperature is within the manufacturer's specified range and that all cooling vents and fins are unobstructed.

  2. 2

    Inspect the inverter's display and event log for concurrent fault codes, warnings, or a history of Fault 7015 to identify patterns.

  3. 3

    Perform a controlled power cycle of the inverter by sequentially disconnecting AC and then DC power, waiting 5 minutes, and then reconnecting DC and then AC power.

  4. 4

    Verify the inverter's firmware version and update to the latest stable release if available, as software improvements may address sensor reading stability or diagnostic accuracy.

Alle Codes in diesem Handbuch durchsuchen (9)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: SMA SUNNY TRIPOWER X Solar Inverter