2

Overvoltage

Vacon · 20 Compact

Was bedeutet 2 ?

The DC-link voltage within the frequency converter has exceeded its internal safety limit. This commonly occurs when the motor regenerates energy back to the drive, especially if the deceleration time is set too short. High overvoltage peaks in the mains supply can also contribute to this fault.

Häufige Ursachen

  • DC bus voltage exceeds safe operating limit.
  • Regenerative braking energy not being dissipated.
  • External braking resistor failure.
  • Overvoltage during deceleration ramps.
  • Input voltage too high for the converter rating.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Increase the deceleration time parameter (Par.4.3 or Par.4.6) to allow for a more gradual stop and reduce regenerative energy.