bUS

Option Communication Error

Yaskawa · iQpump1000

Was bedeutet bUS ?

The connection was lost after establishing initial communication with an option card, or no signal was received from the PLC. This fault is only detected when the run command frequency reference is assigned to an option card.

Häufige Ursachen

  • The connection was lost after establishing initial communication.
  • No signal was received from the PLC.
  • Faulty communications wiring or an existing short circuit.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify all communication cables are securely connected and free from damage or short circuits.

  2. 2

    Correct any faulty wiring or disconnected cables in the communication network.