b06410

Error Applying Mint Motion Library Command

ABB · ACS850 Standard Program Firmware

What does b06410 mean?

This error typically occurs after a firmware upgrade when parameters are being re-instated. It indicates that the new firmware version includes parameters not present in the old parameter file, preventing proper configuration. The drive may not become operational without intervention.

Common Causes

  • Parameter file saved from an older firmware version is incompatible with the newly upgraded firmware, containing obsolete or incorrectly structured data.
  • New firmware introduces new parameters or modifies existing parameter data types, causing errors when loading an old configuration file.
  • Corrupted parameter file being loaded, preventing Mint Motion Library commands from being correctly applied.
  • Sequence of parameter application after firmware upgrade is incorrect, leading to dependency issues.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    After a firmware upgrade, perform a factory reset of the drive (e.g., using Parameter P0-00) to ensure a clean parameter state.

  2. 2

    Manually reconfigure essential parameters or use a parameter file specifically generated for the new firmware version.

  3. 3

    If available, use a firmware upgrade tool that includes a parameter migration utility to convert old parameter files to the new format.

  4. 4

    Connect to the drive with commissioning software and check for warnings or errors during parameter upload, specifically noting any incompatible parameter values.

  5. 5

    Review the firmware release notes for any mandatory parameter changes or configuration requirements after upgrading.

Browse all codes in this manual (57)
Verified technical data. Last updated: March 2026