ABB · Application Error ABB Motion Drives Error trouble shoo
The controller (MotiFlex e180, MicroFlex e190) has detected an ambient temperature lower than -5 °C. The drive cannot be enabled or operated under these conditions to prevent damage or unreliable performance.
Click steps to track your progress.
Increase the ambient temperature around the drive and within the drive cabinet until it is above the minimum operating limit of -5 °C.
Implement appropriate heating solutions for the drive cabinet or installation environment if operating in consistently cold conditions.
Monitor the ambient temperature to ensure it remains within the specified operating range for the MicroFlex e190 or MotiFlex e180 drive before attempting to enable the drive.
Allow sufficient time for the drive to warm up to an acceptable operating temperature.