ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

SUSPEND ACTIVE

Suspend active

ABB · Application Error ABB Motion Drives Error trouble shoo

What does SUSPEND ACTIVE mean?

The drive is in a 'Suspend active' state, indicating that the Mint SUSPEND command is active. This is not an error but a commanded state that prevents the firmware from loading and the drive from transitioning to normal operation.

Common Causes

  • The Mint SUSPEND command has been activated, possibly unintentionally or as part of a debug routine.
  • A previous program execution left the drive in a suspended state.
  • Firmware loading is blocked due to an active suspension command.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Connect to the drive using Mint Workbench and check the status of any active SUSPEND commands.

  2. 2

    Issue a RESUME command from Mint Workbench to clear the suspended state and allow firmware loading to proceed.

  3. 3

    Review the Mint program code for any SUSPEND commands that might be inadvertently activated during boot or initialization.

  4. 4

    Perform a factory reset if unable to clear the suspend state via software, understanding this will clear all parameters.