Replaced C-P
Allen-Bradley · PowerFlex 520-series Adjustable Frequency
What does F107 mean?
The control module is unable to recognize the power module it is attached to, indicating a hardware failure or improper assembly after a module change. The drive cannot establish basic communication or identification with its power section, preventing startup.
Common Causes
- The power module has been physically replaced, and the control module has not been properly initialized to recognize the new power module.
- Data corruption in the control module's non-volatile memory regarding its last known power module ID.
- The control module or power module has experienced an internal hardware failure preventing proper identification during startup.
- Loose or intermittent connection between the control module and the new power module.
- A significant difference in firmware versions or revisions between the control and power modules after a replacement.
Repair Steps & Checklist
Click steps to track your progress.
- 1
1. After replacing the power module, ensure the control module is fully seated and secured, then power cycle the drive (disconnecting all power for 60 seconds).
- 2
2. Access the drive's parameter menu and execute the "Power Module Acknowledge" function (e.g., P0-50 = 1 to acknowledge a new power module ID).
- 3
3. If available, try installing the original control module (if known good) onto the new power module to rule out control module failure.
- 4
4. Inspect the interconnect pins between the control module and the power module for damage or contamination.
- 5
5. Perform a complete parameter reset (e.g., P0-02 = 2) on the drive after replacing the power module, then reload parameters from a backup.