33

Auto Rstrt Tries

Allen-Bradley · PowerFlex 700

What does 33 mean?

The drive has unsuccessfully attempted to reset an active fault and resume running for the programmed number of [Flt RstRun Tries]. This indicates a persistent underlying fault condition that the drive cannot clear automatically. The behavior of this function can be enabled or disabled via [Fault Config 1] on page 1-46.

Common Causes

  • Drive attempted to restart after a transient fault multiple times.
  • Persistent motor load or control issue preventing stable operation.
  • Configuration parameter P0-05 set for automatic restarts.
  • Auto-restart attempts exceeded configured limit.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Review the most recent fault code using parameters 243-257 (e.g., [Fault 1 Code]) to identify the underlying trip cause.

  2. 2

    Verify parameter [Fault Config 1] on page 1-46 to check the auto restart configuration.