Allen-Bradley · PowerFlex 40 Adjustable Frequency
This fault indicates that the drive was commanded to write default parameter values to its EEPROM memory. This action resets all user-configured parameters to their factory default settings.
Click steps to track your progress.
Verify if a factory reset was intentionally performed by reviewing recent operator actions or machine log files.
Reload the last known good parameter set into the drive using a software tool (e.g., Connected Components Workbench) or by manually entering values.
Check parameter P0-53 [Reset to Defaults] to ensure it is set to '0' (No action) after reloading parameters.
Monitor the drive's power supply for stability and proper voltage levels using a true RMS multimeter over several power cycles.
If parameter defaulting persists, back up parameters and then replace the drive, as this may indicate internal memory hardware failure.