Allen-Bradley · PowerFlex 40 Adjustable Frequency
This fault signifies that the autotune function for Sensorless Vector Control (SVC) was either intentionally cancelled by the user or failed to complete successfully. This might prevent optimal motor control.
Click steps to track your progress.
Ensure the motor is completely disconnected from any mechanical load before initiating the autotune process.
Verify that all motor nameplate data (P0-30 to P0-33) is accurately entered into the drive's parameters.
Initiate the autotune function again (e.g., by setting P0-50 [Motor Autotune] to '1' or '2') and allow it to complete without interruption.
Monitor motor current and speed feedback during the autotune for erratic behavior that might indicate motor or cable issues.
If repeated failures occur, perform a manual motor resistance and inductance test using a multimeter/LCR meter and compare values to expected motor data.