Axis type not allowed
Beckhoff · TwinCAT 2 NC
What does 4301 mean?
The value configured for the axis type is unacceptable because it is not defined within the system's supported types. Valid types include 1: Servo, 2: High/low speed, and 3: Stepper motor. An incorrect axis type means the NC cannot apply the correct control algorithms and parameters, leading to axis malfunction.
Common Causes
- Attempt to configure an axis with an invalid type (e.g., P1-02 set to '4') that is not supported by the drive firmware or controller.
- Mismatch between the actual physical motor/drive combination and the configured axis type parameter (P1-02, Axis Type).
- Outdated firmware on the drive or controller that does not support a newly intended axis type configuration.
- Typographical error during manual entry of the axis type parameter (P1-02) via the drive HMI or configuration software.
Repair Steps & Checklist
Click steps to track your progress.
- 1
1. Verify the configured axis type parameter (P1-02) matches one of the defined valid types: 1 (Servo), 2 (High/low speed), or 3 (Stepper motor).
- 2
2. Consult the drive's technical manual for the specific model to confirm the supported axis types and their corresponding numerical values.
- 3
3. Ensure the physical motor connected to the drive is compatible with the selected axis type (e.g., not trying to run a servo motor as a stepper).
- 4
4. If attempting to use a new axis type, check for available firmware updates for the drive and controller that might expand supported types.
- 5
5. Re-enter the axis type parameter (P1-02) carefully using the configuration software to avoid input errors.