F2890

Invalid device code

Bosch Rexroth · IndraDrive MPx02

What does F2890 mean?

The device code detected by the drive is invalid. This code identifies the specific hardware variant or type of the drive or an installed module. An invalid code suggests an incompatibility between hardware components, an incorrectly installed module, or a firmware issue preventing proper device identification. The drive may refuse to operate with unrecognized hardware.

Common Causes

  • Incompatible hardware module installed
  • Incorrect firmware version for the detected hardware
  • Faulty device identification chip on a module
  • Damaged communication link for device identification
  • Incorrect parameter setting for device type

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all installed option modules (e.g., communication, I/O, safety) within the IndraDrive MPx02 for correct physical seating and secure latching/screw connections.

  2. 2

    Verify the compatibility of all installed hardware components and option modules with the specific IndraDrive MPx02 type and its current firmware version using Bosch Rexroth documentation.

  3. 3

    Check the current firmware version of the IndraDrive MPx02 via the HMI or diagnostic software and compare it with the recommended version for the installed hardware configuration.

  4. 4

    Verify drive parameters related to hardware identification, module configuration, or device codes for correct and consistent settings in the drive controller.

Browse all codes in this manual (99)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02