F3142

Activation time of enabling control exceeded

Bosch Rexroth · IndraDrive MPx02

What does F3142 mean?

This non-fatal safety error indicates that the time taken to activate the enabling control (e.g., Safe Torque Off - STO) on the IndraDrive MPx02 has exceeded its permissible limit. This suggests a delay in the safety circuit's response, which can compromise the safety function's effectiveness.

Common Causes

  • Slow response of external safety relays or contactors in the enabling circuit.
  • Excessive capacitance or inductance in the enabling circuit wiring.
  • Incorrect parameterization of the activation time monitoring in the IndraDrive MPx02.
  • Partial short circuit or high resistance in the enabling circuit.
  • Internal hardware fault in the safety-related input or STO circuit of the drive.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure the actual response time of the external safety relays or contactors involved in the enabling circuit.

  2. 2

    Inspect the wiring of the enabling control circuit for excessive length, insufficient wire gauge, or poor connections that could cause delays.

  3. 3

    Verify the configured activation time monitoring parameters in the IndraDrive MPx02 to ensure they are appropriate for the system's response.

  4. 4

    Check the enabling circuit for any partial shorts or high resistance connections that could impede signal activation.

  5. 5

    If the error persists and external components are verified, it may indicate an internal issue with the STO input section of the IndraDrive MPx02.

Browse all codes in this manual (99)
Verified technical data. Last updated: March 2026