825

Insufficient memory for program %s.

Bosch Rexroth · Motion Control

What does 825 mean?

The allocated memory for the link table, defined in MACODA block number 707000010 ('Data areas for CPL programs'), is too small. This results in insufficient memory for the specified program '%s', causing a part program error.

Common Causes

  • Insufficient memory allocated for the link table in MACODA parameter 707000010.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Enlarge the data range for the link table in MACODA parameter 707000010.

  2. 2

    Initiate a new system startup after modifying the parameter.