Bosch Rexroth · Motion Control
An error occurred during the transition to SERCOS phase 0, preventing the selected SERCOS phase from being successfully implemented. This is a servo loop or drive fault, indicating a critical issue in the SERCOS state machine, with no error recovery possible.
Click steps to track your progress.
Measure input supply voltage and DC bus voltage at the affected drive and verify against nominal specifications.
Inspect all SERCOS fiber optic cables for physical damage, proper routing, and secure connections at both controller and drive interfaces.
Verify SERCOS communication parameters (e.g., ring configuration, cycle time, drive address) in both the controller and the drive against the machine's configuration backup.
Check diagnostic LEDs on the SERCOS interface of the drive and controller for communication activity or error indications.