850

SERCOS: Repeated message failure.

Bosch Rexroth · Motion Control

What does 850 mean?

Two successive drive telegrams from the same address have failed, causing the NC to automatically switch back to SERCOS phase 0. This is a servo loop or drive fault, indicating persistent communication problems on the SERCOS network.

Common Causes

  • Failure of two successive drive telegrams from the same SERCOS address.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the SERCOS configuration for correctness.

  2. 2

    Verify the integrity and connections of SERCOS cables.

  3. 3

    Inspect all drives connected to the SERCOS ring for faults.

  4. 4

    Initiate a new SERCOS startup.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026