Parameter value is outside its limits (Specific range)
Danfoss · VLT AutomationDrive FC 301/302
What does 3072–5122 mean?
A parameter has been configured with a value that falls outside its acceptable minimum or maximum range within a specific internal code range. This prevents the drive from operating correctly and can lead to unexpected behavior.
Common Causes
- Manual entry of a parameter value (e.g., P1-54 Motor rated current) exceeding the drive's maximum allowable limit.
- Loading an incorrect parameter set from a different drive model or power rating.
- Autotune or motor identification process attempting to set a physically impossible value for the connected motor.
- Corruption of the parameter value in non-volatile memory (EEPROM or Flash).
- Software calculation error internally generating an out-of-range value that violates defined limits.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Identify the specific parameter code displayed on the LCP associated with this fault.
- 2
Refer to the drive's operating manual to find the valid range (minimum/maximum) for the identified parameter.
- 3
Adjust the parameter value (e.g., P1-54 Motor rated current) to be within its acceptable limits.
- 4
If parameters were loaded from a file, verify the file matches the exact drive model and power rating.
- 5
Perform a factory reset via Parameter P14-22 (Reset options) set to 2 (Load LCP defaults) and re-enter critical parameters.