EL
ErrorLib
Brands
||
  1. Home
  2. Fanuc
  3. Alpha i series AC Servo Motor
  4. 601
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

601

External Radiator Fin Cooling Fan Stopped

Fanuc · Alpha i series AC Servo Motor

What does 601 mean?

This alarm is issued when the fan motor responsible for cooling the external radiator fin of the inverter has failed. This fan is a consumable part. Failure can lead to inverter overheating and potential damage if not addressed.

Common Causes

  • Fan motor for inverter radiator has failed
  • Fan clogged with foreign matter
  • Power connector of the fan is improperly connected

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check that the fan is not clogged with foreign matter

  2. 2

    Check that the power connector of the fan is connected properly

  3. 3

    Replace the fan or the entire servo amplifier module

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

000Power-Down Required Parameter011Zero Feedrate Specified013Maximum Feedrate Zero
Source: Fanuc Alpha i series AC Servo Motor
Open Manual (Page 230)Search more codes in this manual