EL
ErrorLib
Brands
||
  1. Home
  2. Fanuc
  3. Alpha i Series Servo Amplifier
  4. 0475
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

0475

Observer Parameter (POA1) Overflow

Fanuc · Alpha i Series Servo Amplifier

What does 0475 mean?

This invalid parameter setting alarm indicates that the internal calculation value of the observer parameter POA1 has overflowed. This suggests an incorrect setting for the observer parameter, causing internal calculation limits to be exceeded.

Common Causes

  • Observer parameter (POA1) calculation has overflowed.
  • Disturbances affecting observer state prediction.
  • Faulty observer gain tuning (P04-65).
  • Rapid acceleration/deceleration transients.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Correct the setting of the observer parameter to (-1) × (desired value)/10.

Browse all codes in this manual (101)
Verified technical data. Last updated: April 2026

Related Faults

0233Velocity Pulse Count Exceeded0243Position Pulse Count Exceeded0434Velocity Loop Integral Gain Overflow
Source: Fanuc Alpha i Series Servo Amplifier
Open Manual (Page 33)Search more codes in this manual