0535

Dead Zone Compensation Parameter Overflow

Fanuc · Alpha i Series Servo Amplifier

What does 0535 mean?

This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.

Common Causes

  • Dead zone compensation parameter calculation has overflowed.
  • Excessive mechanical slack or play in the drive train.
  • Improper dead zone compensation tuning (P04-12).
  • Variable friction characteristics.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.