EL
ErrorLib
Brands
||
  1. Home
  2. Fanuc
  3. Alpha i Series Servo Amplifier
  4. 0699
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

0699

Velocity Feed-Forward Coefficient Overflow

Fanuc · Alpha i Series Servo Amplifier

What does 0699 mean?

This invalid parameter setting alarm indicates that the internal calculation value of the velocity feed-forward coefficient has overflowed. This typically occurs when the coefficient setting is too high for the system's internal processing limits.

Common Causes

  • Velocity feed-forward coefficient calculation has overflowed.
  • The system is overcompensating for expected velocity.
  • Velocity feed-forward gain parameter (P04-17) is too large.
  • Fast dynamic response is causing calculation instability.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Decrease the velocity feed-forward coefficient to prevent overflow.

Browse all codes in this manual (101)
Verified technical data. Last updated: April 2026

Related Faults

0233Velocity Pulse Count Exceeded0243Position Pulse Count Exceeded0434Velocity Loop Integral Gain Overflow
Source: Fanuc Alpha i Series Servo Amplifier
Open Manual (Page 33)Search more codes in this manual