DS0022

DUAL CHECK SAFETY IS NOT WORKED

Fanuc · Alpha i Series Servo Amplifier

What does DS0022 mean?

The Dual Check Safety function is unavailable because parameter No.1902#6 is set to 0. This disables a critical safety feature of the system, potentially reducing safety integrity.

Common Causes

  • Dual Check Safety (DCS) function did not perform its verification task correctly.
  • Safety signal path interruption between redundant safety circuits.
  • Mismatched safety parameters in the DCS configuration.
  • Failure in the redundant encoder or speed feedback system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Set parameter No.1902#6 to 1 to enable the Dual Check Safety function.

Browse all codes in this manual (101)
Verified technical data. Last updated: April 2026