SV0369

DATA TRANS. ERROR(INT)

Fanuc · Alpha i Series Servo Amplifier

What does SV0369 mean?

A CRC error or stop bit error occurred in the communications data from the built-in Pulsecoder. This signifies data corruption or an improper termination in the serial communication from the internal encoder.

Common Causes

  • Noise or interference corrupting serial data packets from the internal Pulsecoder.
  • Internal Pulsecoder hardware fault causing data corruption.
  • CRC calculation error within the internal Pulsecoder's firmware.
  • Damaged serial interface on the servo drive receiving data.
  • Incorrect stop bit configuration in communication parameters.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure signal integrity of serial data lines (e.g., clock, data) from internal Pulsecoder.

  2. 2

    Ensure proper grounding of the servo drive and internal Pulsecoder.

  3. 3

    Check servo parameter P1-03 (Encoder Serial Protocol) for correct configuration.

  4. 4

    Use an oscilloscope to analyze serial data frames for errors.

  5. 5

    Swap communication cables to rule out cable degradation.

Browse all codes in this manual (101)
Verified technical data. Last updated: April 2026

Related Faults

0233Velocity Pulse Count Exceeded0243Position Pulse Count Exceeded0434Velocity Loop Integral Gain Overflow
Source: Fanuc Alpha i Series Servo Amplifier
Open Manual (Page 127)Search more codes in this manual